1.
Rev. bras. anestesiol ; 70(3): 248-255, May-June 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1137175

RESUMO

Abstract Background and objectives: To assess the agreement between the epidural depth measured from the surgical site with the epidural depths estimated with magnetic resonance imaging (MRI) and ultrasound scanning. Methods: Fifty patients of either sex, scheduled for L4‒5 lumbar disc surgery under general anesthesia were enrolled in this prospective observational study, and the results of 49 patients were analyzed. The actual epidural depth was measured from the surgical site with a sterile surgical scale. The MRI-derived epidural depth was measured from the MRI scan. The ultrasound estimated epidural depth was measured from the ultrasound image obtained just before surgery. Results: The mean epidural depth measured from the surgical site was 53.80 ± 7.67 mm, the mean MRI-derived epidural depth was 54.06 ± 7.36 mm, and the ultrasound-estimated epidural depth was 53.77 ± 7.94 mm. The correlation between the epidural depth measured from the surgical site and MRI-derived epidural depth was 0.989 (r2 = 0.979, p < 0.001), and the corresponding correlation with the ultrasound-estimated epidural depth was 0.990 (r2 = 0.980, p < 0.001). Conclusions: Both ultrasound-estimated epidural depth and MRI-derived epidural depth have a strong correlation with the epidural depth measured from the surgical site. Preprocedural MRI-derived estimates of epidural depth are slightly deeper than the epidural depth measured from the surgical site, and the ultrasound estimated epidural depths are somewhat shallower. Although both radiologic imaging techniques provided reliable preprocedural estimates of the actual epidural depth, the loss of resistance technique cannot be discarded while inserting epidural needles.


Resumo Justificativa e objetivos: Avaliar a concordância entre a profundidade peridural medida no campo cirúrgico com a profundidade peridural estimada pela Ressonância Magnética (RM) e ultrassonografia. Métodos: Cinquenta pacientes de ambos os sexos agendados para cirurgia de disco lombar L4-5 sob anestesia geral foram incluídos neste estudo observacional prospectivo, e os resultados de 49 pacientes foram analisados. A profundidade peridural real foi medida no campo cirúrgico com uma régua cirúrgica estéril. A profundidade peridural obtida pela Ressonância Magnética (RM) foi medida a partir das imagens do exame de RM. A profundidade peridural estimada pelo ultrassom foi medida a partir da imagem do ultrassom obtida imediatamente antes da cirurgia. Resultados: A profundidade peridural média medida no campo cirúrgico foi de 53,80 ± 7,67 mm; a profundidade peridural média da RM foi de 54,06 ± 7,36 mm; e a profundidade peridural estimada por ultrassom foi de 53,77 ± 7,94 mm. A correlação entre a profundidade peridural medida no campo cirúrgico e a profundidade peridural derivada da RM foi de 0,989 (r2 = 0,979; p < 0,001); e a correlação correspondente com a profundidade peridural estimada por ultrassom foi de 0,990 (r2 = 0,980; p < 0,001). Conclusões: Tanto a profundidade peridural estimada por ultrassom quanto a profundidade peridural derivada da RM mostram forte correlação com a profundidade peridural medida no campo cirúrgico. As estimativas pré-operatórias da profundidade peridural derivadas da RM são um pouco mais profundas do que a profundidade peridural medida no campo cirúrgico, e as profundidades peridurais estimadas por ultrassom são um pouco mais rasas. Embora ambas as técnicas de imagem radiológica tenham fornecido estimativas pré-operatórias confiáveis da profundidade peridural real, a técnica de perda de resistência não pode ser descartada durante a inserção da agulha peridural.


Assuntos
Humanos , Masculino , Feminino , Adulto , Imageamento por Ressonância Magnética , Espaço Epidural/anatomia & histologia , Espaço Epidural/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares , Tamanho do Órgão , Estudos Prospectivos , Ultrassonografia , Correlação de Dados , Período Intraoperatório , Pessoa de Meia-Idade
2.
Rev. bras. anestesiol ; 63(5): 385-388, set.-out. 2013. ilus
Artigo em Português | LILACS | ID: lil-691370

RESUMO

JUSTIFICATIVA E OBJETIVOS: O objetivo deste estudo foi desenvolver uma técnica simples e prática para a cateterização crônica em canal peridural sacral de coelhos. MÉTODOS: O estudo incluiu dez coelhos com peso entre 2 e 2,5 kg. Após a anestesia e a analgesia, colocamos um cateter peridural através de uma incisão longitudinal de 2 cm na cauda acima da região do hiato sacral. Confirmamos a localização com a administração de lidocaína a 1% (nivelamento da perda sensorial e da função motora dos membros inferiores). O cateter foi introduzido através de um túnel subcutâneo até o pescoço, onde foi fixado. RESULTADOS: A implantação de cateter crônico peridural caudal foi bem-sucedida em todos os coelhos. Os cateteres permaneceram eficazmente no lugar por dez dias, sem intercorrências durante esse período. A localização do cateter foi reconfirmada por lidocaína a 1% no último dia. Após matar os animais, procedeu-se laminectomia para localização do cateter no espaço peridural. CONCLUSÕES: Há vários métodos de cateterização do espaço peridural em modelos animais na literatura. A cateterização do espaço peridural em coelhos pode ser feita através das vias atlanto-occipital, lombar ou caudal por amputação da cauda. As técnicas de cateterização intratecal e peridural descritas na literatura exigem perícia cirúrgica e conhecimento de procedimentos cirúrgicos, como laminectomia e amputação da cauda. A nossa técnica não requer grande habilidade cirúrgica, a integridade anatômica foi preservada e não houve mau posicionamento de cateter. Em conclusão, podemos sugerir que a nova técnica de cateterização peridural é simples, facilmente aplicável e pode ser usada em estudos experimentais de modelos animais.


INTRODUCTION: In this study we aimed to develop a simple and practical technique for chronic sacral epidural catheterization of rabbits. METHODS: We included ten rabbits weighing 2-2.5 kg in the study. After anesthesia and analgesia, we placed an epidural catheter by a 2cm longitudinal skin incision in the tail above the sacral hiatus region. We confirmed localization by giving 1% lidocaine (leveling sensory loss and motor function loss of the lower extremity). The catheter was carried forward through a subcutaneous tunnel and fixed at the neck. RESULTS: Chronic caudal epidural catheter placement was succesful in all rabbits. The catheters stayed in place effectively for ten days. We encountered no catheter complications during this period. The localization of the catheter was reconfirmed by 1% lidocaine on the last day. After animals killing, we performed a laminectomy and verified localization of the catheter in the epidural space. CONCLUSIONS: Various methods for catheterization of the epidural space in animal models exist in the literature. Epidural catheterization of rabbits can be accomplished by atlanto-occipital, lumbar or caudal routes by amputation of the tail. Intrathecal and epidural catheterization techniques defined in the literature necessitate surgical skill and knowledge of surgical procedures like laminectomy and tail amputation. Our technique does not require substantial surgical skill, anatomical integrity is preserved and malposition of the catheter is not encountered. In conclusion, we suggest that our simple and easily applicable new epidural catheterization technique can be used as a model in experimental animal studies.


JUSTIFICATIVA Y OBJETIVOS: El objetivo de este estudio fue desarrollar una técnica sencilla y práctica para la cateterización crónica en canal epidural sacral de conejos. MÉTODOS: El estudio incluyó diez conejos con peso entre 2 y 2,5 kg. Después de la anestesia y la analgesia, pusimos un catéter epidural por medio de una incisión longitudinal de 2 cm en la cola por encima de la región del hiato sacral. Confirmamos la localización con la administración de lidocaína al 1% (nivelación de la pérdida sensorial y de la función motora de los miembros inferiores). El catéter se introdujo por medio de un túnel subcutáneo hasta el cuello, en dónde finalmente se fijó. RESULTADOS: La implantación de catéter crónico epidural de cola fue exitosa en todos los conejos. Los catéteres permanecieron eficazmente en el lugar por diez días, sin intercurrencias durante ese período. La ubicación del catéter fue reconfirmada por la lidocaína al 1% en el último día. Después de sacrificar a los animales, se procedió a la laminectomía y se verificó la ubicación del catéter en el espacio epidural. CONCLUSIONES: En la literatura existen varios métodos de cateterización del espacio epidural en modelos animales. La cateterización del espacio epidural en conejos puede ser hecha por medio de las vías atlanto-occipital, lumbar o de cola por amputación de la cola. Las técnicas de cateterización intratecal y epidural descritas en la literatura exigen una pericia quirúrgica y el conocimiento de procedimientos quirúrgicos, como la laminectomía y la amputación de la cola. Nuestra técnica no requiere gran habilidad quirúrgica, la integridad anatómica se preservó y no hubo un mal posicionamiento del catéter. Como conclusión, podemos sugerir que la nueva técnica de cateterización epidural es sencilla, fácilmente aplicable y que puede ser usada en estudios experimentales de modelos animales.


Assuntos
Animais , Coelhos , Cateterismo/métodos , Espaço Epidural/anatomia & histologia , Região Lombossacral
3.
Rev. bras. anestesiol ; 60(4): 376-382, jul.-ago. 2010. ilus, graf
Artigo em Inglês, Português | LILACS | ID: lil-554323

RESUMO

JUSTIFICATIVA E OBJETIVOS: O objetivo deste estudo foi avaliar o uso do ultrassom na determinação da profundidade do espaço peridural. MÉTODO: Sessenta pacientes foram alocados prospectivamente tendo a identificação do espaço intervertebral L3-L4 inicialmente feita pelo método palpatório. Posteriormente, utilizou-se o método ultrassonográfico, realizando-se a medida da profundidade do espaço peridural (PU). Após a punção peridural, foram anotadas as medidas da profundidade (PA). Realizaram-se estatísticas descritivas dos dados e calculou-se o coeficiente de correlação de concordância e análise de Bland-Altman, com intervalo de 95 por cento de confiança para as medidas de profundidade. RESULTADOS: A análise de concordância entre o método palpatório e ultrassonográfico foi de 86,6 por cento. Foram obtidos valores médios de PU 4,97 ± 0,51 cm e PA 4,97 ± 0,71 cm e coeficiente de correlação de Pearson de 0,66, enquanto a análise Bland-Altman revelou diferença média de 0,0035 ± 0,53 cm, com limite de 95 por cento de confiança entre -0,228 a 0,221. CONCLUSÕES: A ultrassonografia é uma ferramenta precisa para a determinação da profundidade do espaço peridural.


BACKGROUND AND OBJECTIVES: The objective of the present study was to evaluate the use of the ultrasound on the determination of the depth of the epidural space. METHODS: Sixty patients were included in this prospective study; the L3-L4 space was initially identified by palpation followed by the ultrasound measuring the depth of the epidural space (PU). After the epidural puncture the measurements o the depth (PA) were recorded. The data underwent descriptive statistics, and the concordance correlation coefficient and Bland-Altman analysis, with 95 percent confidence interval were calculated. RESULTS: Analysis of concordance between the palpation and ultrasound methods was 86.6 percent. Mean values of PU obtained were 4.97 ± 0.51 cm and PA 4.97 ± 0.71 cm, and Pearson correlation coefficient of 0.66 while Bland-Altman analysis revealed a mean difference of 0.0035 ± 0.53 cm with 95 percent confidence interval between -0.228 and 0.221. CONCLUSIONS: The ultrasound is a precise tool to determine the depth of the epidural space.


JUSTIFICATIVA Y OBJETIVOS: El objetivo de este estudio fue evaluar el uso del ultrasonido para la determinación de la profundidad del espacio epidural. MÉTODO: Sesenta pacientes fueron ubicados, prospectivamente teniendo la identificación del espacio intervertebral L3-L4 inicialmente realizada por el método de palpación. Posteriormente se usó el método de ultrasonido, y se realizó la medida de la profundidad del espacio epidural (PU). Después de la punción epidural, se anotaron las medidas de la profundidad (PA). Se midieron las estadísticas descriptivas de los datos y se calculó el coeficiente de correlación de concordancia y análisis de Bland-Altman, con un intervalo de un 95 por ciento de confianza para las medidas de profundidad. RESULTADOS: El análisis de concordancia entre el método de palpación y el ultrasonido fue de un 86,6 por ciento. Se obtuvieron valores promedios de PU 4,97 ± 0,51 cm y PA 4,97 ± 0,71 cm y un coeficiente de correlación de Pearson de 0,66, mientras el análisis Bland-Altman arrojó una diferencia promedio de 0,0035 ± 0,53 cm, con un límite de un 95 por ciento de confianza entre -0,228 a 0,221. CONCLUSIONES: El ultrasonido es un instrumento preciso para la determinación de la profundidad del espacio epidural.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espaço Epidural/anatomia & histologia , Espaço Epidural , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Rev. argent. anestesiol ; 63(6): 402-406, nov.-dic. 2005.
Artigo em Espanhol | LILACS | ID: lil-431482

RESUMO

Las inyecciones cervicales epidurales de esteroides se realizan comúnmente en pacientes con cuadros dolorosos en esa región, incluyendo patología discal degenerativa, síndrome post-laminectomía, dolores cervicales radiculares, etc. El mecanismo de acción aún no se conoce con claridad, pero se especula que los esteroides inyectados cerca del área afectada disminuyen el proceso inflamatorio responsable del dolor. El propósito de este procedimiento puede ser terapéutico o diagnóstico, y realizarse por vía interlaminar o transforaminal. En los últimos años, se han informado complicaciones severas con el uso de este tipo de inyecciones. En esta revisión discutiremos las bases anatómicas por las cuales una técnica puede preferirse a otra, así como los pro y contra de cada uno de estos procedimientos, con una breve visión general acerca de las mejores alternativas y sugerencias para evitar complicaciones catastróficas.


Assuntos
Humanos , Cervicalgia/tratamento farmacológico , Cervicalgia/terapia , Espaço Epidural/anatomia & histologia , Espaço Epidural/irrigação sanguínea , Injeções Epidurais/efeitos adversos , Injeções Epidurais/instrumentação , Injeções Epidurais/métodos , Cuidados Pós-Operatórios/normas , Esteroides/administração & dosagem , Consentimento Livre e Esclarecido , Decúbito Ventral , Vértebras Cervicais/anatomia & histologia
6.
Rev. mex. anestesiol ; 20(3): 110-5, jul.-sept. 1997. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-225077

RESUMO

El cada vez más frecuente abordaje del espacio epidural o intratecal con fines diagnósticos, pronósticos y/o terapéuticos, que permitan la invasión de éstos en forma aguda o crónica obligan a identificar la ubicación de los catéteres instalados y la posible distribución de los agentes depositados a través de ellos; por lo que nos propusimos evaluar experimentalmente si el epidurograma cumple esta función, además de conocer algunas particularidades de la vía espinal. Con base a este objetivo se implantan 64 ratas Wistar con catéteres epidurales por microcirugía, administrando material radiopaco, efectuando estudio radiológico y evaluación neuroconductal (tiempo de retiro de las patas y cola) al frió y calor, encontrando hallasgos radiológicos que se corroboraron con el estudio necrológico, y a su vez correlacionando resultados con las estimaciones neurofuncionales, lo que sugiere que la epidurografía es un método consistente y confiable; resultando una herramienta eficaz para la exploración del espacio epidural


Assuntos
Animais , Ratos , Pentobarbital/administração & dosagem , Ratos Wistar , Espaço Epidural/anatomia & histologia , Espaço Epidural , Animais/anatomia & histologia , Animais de Laboratório , Dissecação , Modelos Anatômicos
7.
Rev. argent. radiol ; 59(1): 1-34, ene.-mar 1995. ilus
Artigo em Espanhol | LILACS | ID: lil-151450

RESUMO

El proceso degenerativo del raquis lumbar es la causa principal de un trastorno clínico denominado Síndrome del canal estrecho lumbar. Varias hipótesis tratan de explicar este síndrome: la teoría postural y la teoría vascular-isquémica, aunque ambas pueden correlacionarse. Los síntomas y signos del canal estrecho son más frecuentes entre la sexta y octava década de vida, afectando a ambos sexos. El diagnóstico por imágenes juega un importante rol e incluye radiografías simples estáticas, TC, RM y la radiculografía dinámica. El canal estrecho puede ser central o de los recesos laterales y afecta con mayor frecuencia al cuarto espacio. Puede ser monofocal o polifocal. Su tratamiento es sintomático o quirúrgico, dependiendo de la gravedad de la estenosis y del cuadro neurológico. La casuística que presentamos corresponde a un período de 20 años con 150 pacientes intervenidos quirúrgicamente


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Espaço Epidural/anatomia & histologia , Canal Medular , Estenose Espinal/diagnóstico , Diagnóstico Diferencial , Dor Lombar/etiologia , Dor Lombar/fisiopatologia , Dor Lombar , Espaço Epidural , Espectroscopia de Ressonância Magnética , Canal Medular/anatomia & histologia , Estenose Espinal/classificação , Estenose Espinal/cirurgia , Tomografia Computadorizada por Raios X
8.
Rev. mex. anestesiol ; 16(1): 11-4, ene.-mar. 1993. tab
Artigo em Espanhol | LILACS | ID: lil-121292

RESUMO

Estudiamos la distancia de la piel al espacio epidural lumbar en una población de 100 mujeres no embarazadas (grupo I) y 100 mujeres embarazadas a término (grupo II), todas con edades entre 18 y 40 años para determinar si existe relación directa entre peso, talla y distancia de la piel al espacio epidural lumbar y conocer si esta relación se modifica el término del embarazo. El bloqueo epidural se efectuó a nivel L2-L3 con abordaje en la línea media y en decúbito lateral, la profundidad del espacio epidural se midió marcado de aguja de Tuohy y midiendo esta distancia en cada paciente. Los datos fueron analizados por regresión lineal, encontrando que existe relación directa entre peso y distancia de la piel al espacio epidural en ambos grupos: Grupo I, r = 0.34, grupo II r = 0.40, pero no hubo relación directa entre talla y distancia de la piel al espacio epidural en ambos grupos: Grupo I, r = 0.28. Las medias de la profundidad fueron: grupo I, 4.59 y grupo II, 4.58 cm, con valor de P > 0.20, no existiendo diferencia significativa entre los grupos.


Assuntos
Humanos , Feminino , Gravidez , Adulto , Peso Corporal , Espaço Epidural/anatomia & histologia , Anestesia Epidural , Punção Espinal/métodos , Gravidez
10.
Med. cir ; 34(1): 17-8, jan.-jun. 1988. ilus
Artigo em Português | LILACS | ID: lil-99780

RESUMO

Durante a execucao da Anestesia Peridural Sacra(APS) apresenta como particularidade a passagem da agulha pela membrana sacrococcigea. Para a confirmacao da ponta da agulha no Espaco Peridural Sacro (EPS) estes dois sinais apresentam elevado indice de fidelidade


Assuntos
Humanos , Masculino , Feminino , Anestesia Epidural , Espaço Epidural/anatomia & histologia
11.
Med. cir ; 34(1): 52-4, jan.-jun. 1988. tab
Artigo em Português | LILACS | ID: lil-99786

RESUMO

A anestesia peridural sacra e perfeitamente exequivel nas urgencias pediatricas. Ela proporciona boa analgesia tras e pos-operatoria. Este trabalho objetiva incentivar a tecnica em tais circunstancias


Assuntos
Criança , Humanos , Masculino , Feminino , Anestesia Epidural , Espaço Epidural/anatomia & histologia , Serviços Médicos de Emergência
12.
Rev. Centro Policlín. Valencia ; 4(1): 61-75, ene.-jun. 1986. tab
Artigo em Espanhol | LILACS | ID: lil-46647

RESUMO

Se estudiaron 146 pacientes embarazadas en las cuales se realizó anestesia peridural simple a nivel T12-L1 y L1-L2 para cesárea segmentaria. Se relacionan la influencia de las variables peso, talla y el cociente peso/talla sobre la distancia piel - espacio peridural (PP), encontrándose una relación directa entre el peso y el cociente peso/talla la distancia PP., no hubo relación entre la talla y la distancia PP. La mayor parte de la población estudiada, (N = 101; 69,18%) presentó una distancia PP entre 2,9 y 4,25cm. Estos datos pueden ser tomados como guía, durante la realización de la anestesia peridural en embarazadas, teniendo en cuenta el margen de error que implica cualquier estudio y la presencia de otras variables no investigadas


Assuntos
Gravidez , Adolescente , Adulto , Pessoa de Meia-Idade , Humanos , Feminino , Anestesia Epidural , Cesárea , Espaço Epidural/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS